One Operator Continuous Monitor
Botron’s Single Operator Continuous Monitor is designed to monitor resistance of the operator’s path to ground. It comes with a built in audible alarm and LED, triggering either when the operator falls out of spec, becomes disconnected, or ground is lost. It is a fixed resistor system and is go/no go. A full time monitoring system is necessary to reduce latency on the assembly line.
Overview
Single conductor (more commonly called single wire) ESD wrist strap monitors detect capacitance. These simplified monitors sense the input connection but do not discern precision resistance. It also offers additional value by monitoring the ground connection at the mat. The built-in LED offers local visual alerts, and a small piezo buzzer offers a nice clear audible alert to the operator at the bench.
This is an entry point to monitoring personnel at the bench. If you are only verifying your Single Wire ESD Wrist Straps via a ESD tester it is possible your wrist strap may fail or the operator may exceed the allowable resistance path to ground while at the bench, exposing sensitive components to electrostatic discharge.
What’s your Type?
Universal support for a standard 4mm banana type grounding coil cords.
Single Wire Connection
Supports 1 operator via Single Wire ESD Wrist Strap.
Local Alerts
A multi-color LED and piezo buzzer provide the operator with both visual and audible feedback in the event of a ground system fault.
Ground Alarm
Alarms when and if grounding connection is lost.
Technical Information
Operator
- Low Fail - <675k
- Pass - >750k to <8meg
- Fail High - >8.5meg
- ± 10%
Condition
- Safe - 1meg
- Fault - 6.5meg
Power
Visual Alarm
- Green LED - Safe
- Red LED - Fault