Botron Company Inc.

Botron Company Inc. home page header image

Ionizing Air Snake – B48614SF

Botron’s Ionizing Air Snake is designed to neutralize static charge eliminate contaminates. It features a self contained HV power unit, foot pedal, and adjustable neck. As with all Botron ionizers, it is equipped with auto ion balance and abnormal HV alarm system.

Features

Specifications

Part Numbers

ionizing-air-snake

Features

Overview:
The B48614SF ionizing Snake is the perfect solution for those who need pin point ionization of static sensitive components. While eliminating static charge it also removes any charged particles or debris that can collect on components. The adjustable neck provides the freedom of use for operators as well as precision ionization.

Notes:
Light weight and compact design
Auto ion balance
Abnormal HV alarm
Adjustable neck
Uses both compressed air and nitrogen
LED indicators
Built in HV power supply
Alloy discharge needle

Click here to download Spec Sheet

Mounting:
The compact design of the ion snake requires minimal room on the work surface. All ionizing snakes should be placed within the specified range for proper ionization of static sensitive components.

Applications:
As with all of Botron’s ionization units the ionizing snake is designed neutralize electrostatic charge in personal bench top environments, sensitive materials assembly, packaging, clean room and laboratories. The versatile adjustable neck of the ion snake makes this an exceptional unit for work stations where space is limited and for those tricky and tight areas only a precision ionizer gun or snake can provide.

Specifications

Performance:
Ion balance +/- 10v
Positive decay times range from (sec) 0.5 at 3 kgf/cm2 to 0.2 at 6 kgf/cm2
Negative decay times range from (sec) 0.5 at 3 kgf/cm2 to 0.2 at 6 kgf/cm2i

*All results are based according to EOS/ESD-STM 3.1-2000.
*Results may vary based on test conditions.

Detailed Info:

  • Power supply
  • Output HV
  • Air pressure range
  • Air pressure range (filter)
  • Air input
  • Ozone Density
  • Indicators
  • Controls
  • Emitter
  • Air line connector
  • Weight
  • AC100 – 240V 50/60Hz
  • AC2200V
  • 2 – 7 kgf/cm2
  • 1 – 7 kgf/cm2
  • Compressed air or N2 without oil and water
  • <.01ppm
  • Green LED, Red LED
  • On/Off button
  • Alloy
  • ¼ NPT
  • 1 lb

Trouble shooting:
The abnormal HV alarm and the red light indicator will alarm if the following problems occur.
Low output HV
Short circuit
Abnormal HV discharge
Wet air flow
Rapid turning on and off of photoelectric switch

© 2015 Botron Company Inc.